Commercial storage system
Confirm the selected equipment and quantities with the project team.
SOLAR ESS HUB
Solutions · Commercial & industrial
PROJECT OBJECTIVES
Combine solar generation, battery storage and energy management for factories, warehouses, retail sites and business parks, with a configuration based on self-consumption, peak demand and critical loads.
This page provides an early solution framework, not a final design. Equipment, capacity and technical boundaries require confirmation by the project engineering team.
SYSTEM COMPONENTS
The equipment, quantities and controls depend on the project. Use this starting list to prepare your enquiry.
Confirm the selected equipment and quantities with the project team.
Confirm the selected equipment and quantities with the project team.
Confirm the selected equipment and quantities with the project team.
Confirm the selected equipment and quantities with the project team.
Product ranges to review for this topic: Hithium Commercial & Industrial Storage · GoodWe Commercial & Industrial Inverter
Related product references: Hithium ESS Cabinet 125kW / 261kWh — Energy storage system · GOODWE GW100K-GT — String inverter
PROJECT INPUTS
Start with the information you have. We will identify any missing details.
Sites with steady daytime demand and a suitable roof can first assess solar self-consumption. Storage can absorb surplus generation for later use. Where load peaks are pronounced, batteries may support peak shaving. Time-of-use optimisation depends on local tariffs, conversion losses and battery life.
PV modules and inverters convert solar energy. The battery and BMS monitor cell conditions, the PCS converts power in both directions, and the EMS schedules operation using generation, demand, tariffs and battery status. Distribution, protection, metering, communications, cooling and fire protection must be coordinated.
Self-consumption first: supply local loads, then store or export surplus where permitted. Peak shaving: discharge near the chosen demand threshold while preserving usable energy. Critical-load backup: reserve battery energy and provide island-capable conversion, switching, protection and a dedicated load circuit. A standard grid-connected system does not automatically supply power during an outage.
PV size depends on roof structure, area, solar resource and grid conditions. Battery power in kW describes instantaneous output; energy in kWh determines duration. A constant 100 kW critical load running for two hours needs about 200 kWh at the load. Nameplate battery capacity must also allow for usable depth of discharge, efficiency, reserve and degradation.
Build a baseline from actual demand and tariffs before comparing configurations. Include equipment, installation, maintenance, conversion losses, degradation and possible replacement costs. Savings and payback vary by project. Confirm local interconnection, structural, electrical and fire requirements, equipment compatibility, acceptance criteria and maintenance responsibilities before construction.
Send the country and city, the last 12 months of electricity bills, interval load data, transformer and connection capacity, roof or site information, existing PV details, critical loads, backup duration and delivery schedule. Available documents are enough to start the discussion.
Technical reference: U.S. Department of Energy — Energy Storage
START PROJECT REVIEW
We can then review the equipment scope, required documents and delivery plan.